C&N, Hebei Hongcheng Pipe Fittings Industry Co., Ltd. is pleased to announce that our ASME SA516 GR60 pressure vessel steel plate has successfully passed Hydrogen-Induced Cracking (HIC) testing conducted by Hebei Mingtai Hengye Testing Technology Co., Ltd. (CNAS Accredited Laboratory). All test specimens achieved zero cracks, meeting the typical acceptance criteria referenced under NACE TM0284-2016 — another milestone in C&N Hebei Hongcheng's manufacturing capability for sour service piping materials.
Test Results: Zero Cracks Across All Parameters
Testing was performed in accordance with NACE TM0284-2016, simulating severe sour service (wet H₂S) conditions. Specimens were continuously immersed for 96 hours at 25±3°C in Solution A (5% NaCl + 0.5% CH₃COOH) saturated with H₂S gas.
| Parameter | Test Result | Typical Acceptance Criteria | Performance |
|---|---|---|---|
| CLR (Crack Length Ratio) | 0% | ≤ 15% | Excellent |
| CTR (Crack Thickness Ratio) | 0% | ≤ 5% | Excellent |
| CSR (Crack Sensitivity Ratio) | 0% | ≤ 2% | Excellent |
All 9 inspection sections (3 specimens × 3 cross-sections) were completely crack-free, well within the typical industry acceptance thresholds — confirming the exceptional hydrogen-induced cracking resistance of C&N Hebei Hongcheng's SA516 GR60 steel plate under sour service conditions.
- SA516 GR60 specimens immersed in H₂S-saturated test solution
- Professional HIC test apparatus with precise H₂S concentration and pH control system
- Standard dimension HIC test specimens before testing – SA516 GR60 steel plate
- Multiple specimens undergoing simultaneous 96-hour corrosion exposure test
Technical Significance
HIC resistance is a critical performance metric for pressure vessel and pipeline steels used in H₂S-containing environments, directly affecting operational safety in oil & gas production, refining, and natural gas transmission. SA516 GR60 is a widely used grade for medium-to-low temperature pressure vessels, applied in reactors, heat exchangers, and storage tanks across refineries and gas processing plants.
This result reflects C&N Hebei Hongcheng's process control across three areas:
- Clean steel melting with tight impurity control
- Optimized rolling parameters for a uniform microstructure
- Precision heat treatment for consistent mechanical properties
- Test solution quality monitoring throughout the 96-hour exposure period
- CNAS-accredited laboratory testing environment with strict quality control
- Specimen surface inspection after HIC test – no cracks detected on any of the inspection surfaces
- Specimen preparation for detailed cross-sectional metallographic examination
About C&N Hebei Hongcheng Pipe Fittings Industry
C&N Hebei Hongcheng maintains a quality control system spanning raw material inspection through final delivery, with products manufactured to ASME, ASTM, API, DIN, and EN standards and full third-party inspection available on request. Our product range includes elbows, tees, reducers, flanges, pressure vessel plates, and custom-engineered piping components, serving the oil & gas, petrochemical, and power generation industries worldwide.
This HIC test result reinforces C&N Hebei Hongcheng's position as a reliable supplier for sour service projects, and reflects our ongoing investment in R&D for demanding oil & gas and refining applications.