en-10253-1-reducer-form-1
All dimensions are in "mm" unless noted otherwise specified.
All weights are in "kg".
you may also check non standard sizes pipe fitting weight online calculation, pipe fitting surface area online calculation,pipe fitting surface volume online calculation from our pipeline tool link:
https://alloypipefitting.com/fitting-calculator.html
The whole weight and dimension list of pipe fitting directory
https://alloypipefitting.com/fitting-dimension-and-weight.html
Download the PDF file: EN-10253-1-butt-weld-fittings-2007
| EN 10253-1 BUTT WELDING PIPE FITTINGS | ||||
| ELBOW 2D | ELBOW 3D | ELBOW 5D | REDUCER FORM 1 | REDUCER FORM 2 |
| EQUAL TEES | REDUCING TEES | DISHED ENDS | CAPS | Tolerance |
1. Technical drawings for EN 10253-1 reducers of form 1

According to EN 10253-1, concentric reducers can be divided into form 1 and form 2. The first figure of above drawing is form 1 and the second one is form 2. The third figure is the technical drawing of eccentric reducer.
2. Dimensions of EN 10253-1 reducers of form 1
| Side D | Side D1 | Length | ||||
| DN | D | T | DN | D1 | T1 | L |
| 25 | 33.7 | 2.6 | 20 | 26.9 | 2.3 | 35 |
| 32 | 42.4 | 2.6 | 20 25 |
26.9 33.7 |
2.3 2.6 |
51 39 |
| 40 | 48.3 | 2.6 | 20 25 32 |
26.9 33.7 42.4 |
2.3 2.6 2.6 |
67 55 38 |
| 50 | 60.3 | 2.9 | 25 32 40 |
33.7 42.4 48.3 |
2.6 2.6 2.6 |
77 61 50 |
| 65 | 76.1 | 2.9 | 32 40 50 |
42.4 48.3 60.3 |
2.6 2.6 2.9 |
95 84 63 |
| 80 | 88.9 | 3.2 | 40 50 65 |
48.3 60.3 76.1 |
2.6 2.9 2.9 |
108 86 56 |
| 100 | 114.3 | 3.6 | 50 60 80 |
60.3 76.1 88.9 |
2.9 2.9 3.2 |
143 114 90 |
| 125 | 139.7 | 4.0 | 65 80 100 |
76.1 88.9 114.3 |
2.9 3.2 3.6 |
159 135 88 |
| 150 | 168.3 | 4.5 | 80 100 125 |
88.9 114.3 139.7 |
3.2 3.6 4.0 |
189 141 94 |
| 200 | 219.1 | 6.3 | 100 125 150 |
114.3 139.7 168.3 |
3.6 4.0 4.5 |
210 170 130 |
| 250 | 273.0 | 6.3 | 125 150 200 |
139.7 168.3 219.1 |
4.0 4.5 6.3 |
250 220 130 |
| 300 | 323.9 | 7.1 | 150 200 250 |
168.3 219.1 273.1 |
4.5 6.3 6.3 |
290 215 130 |
| 350 | 355.6 | 8.0 | 150 200 250 300 |
168.3 219.1 273.1 323.9 |
4.5 6.3 6.3 7.1 |
335 255 125 100 |
| 400 | 406.4 | 8.8 | 200 250 300 350 |
219.1 273.1 323.9 355.6 |
6.3 6.3 7.1 8 |
330 250 175 130 |
*D: Outside diameter of large end of the reducer. T: Wall thickness of the large end.
*D1: Outside diameter of small end of the reducer. T1: Wall thickness of the small end.
*L: Face to face length of reducers.
*All dimensions are in mm unless otherwise specified.
1. Tolerances on dimension according to EN 10253-1
1) All diameters of EN 10253-1 pipe fittings shall be measured at the welding ends of the fittings. The tolerance is ±1% or ±0.5 mm whichever is the greater.
2) In order to ensure the flow-way area through the fitting is not excessively reduced, the internal diameter(not applicable to dished ends and caps) shall be greater than 80% of the theoretical internal diameter(ID), as calculated by: ID = OD - 2T.
3) Tolerances for ovality are:
at the welding ends: 2%;
on the body for elbows and return bends: 4%.
The ovality(Ov) shall be calculated by:
Ov = 200 * (Dmax - Dmin) / (Dmax + Dmin) in %.
Dmax: maximum measured diameter in one section.
Dmin: minimum measured diameter in one section.
4) Wall thickness tolerances
| D | T | Tolerance | |
| mm | mm | minus | plus |
| ≤406.4 | ≤4 >4 |
-12.50% | 0.35 |
*D: Outside diameter at the welding end. T: Wall thickness.
*The minus tolerance also applies to the body of the fitting.
5) Tolerances on specific dimensions
| D | F-G-H | B | C | K | L |
| ≤114.3 | ±2 | ±7 | ±7 | ±4 | ±2 |
| 114.3<D≤219.1 | ±2 | ±7 | ±7 | ±7 | ±3 |
| 219.1<D≤406.4 | ±3 | ±7 | ±10 | ±7 | ±5 |
*D: outside diameter;
*F: distance from the axis of the center line to the face of the branch outlet of equal tee.
*G: distance from the axis of the center line to the face of the branch outlet of reducing tee.
*H: Face to center-line distance for 45°.
*B: Face to top distance for 180° return bends.
*C: Center to center distance for 180° return bends.
*K: height of dished ends or caps.
*L: Face to face length of reducers(both concentric & eccentric).
6) Tolerances on the form of fittings
The tolerance on the form of each type of fitting Q = 1% of the outside diameter(D) or 1 mm, whichever is greater. See the figure illustrated below.